Short circuit impedance
Measures the impedance during short circuit conditions.
| Specification | Value |
|---|---|
| Availability | standard |
- Enhances testing accuracy
A dedicated van for efficient transformer testing and diagnostics.

Measures the impedance during short circuit conditions.
| Specification | Value |
|---|---|
| Availability | standard |
Assesses power losses under different conditions.
| Specification | Value |
|---|---|
| Availability | standard |
Analyzes the frequency response of transformers.
| Specification | Value |
|---|---|
| Availability | standard |

Evaluates moisture levels in transformer insulation.
| Specification | Value |
|---|---|
| Availability | standard |
Provides an intuitive interface for test management.
| Specification | Value |
|---|---|
| Availability | option |
Manages the testing processes and data collection.
| Specification | Value |
|---|---|
| Availability | option |
Tests winding resistance and continuity of tap changers.
| Specification | Value |
|---|---|
| Availability | option |
Verifies turns ratio and vector group of transformers.
| Specification | Value |
|---|---|
| Availability | option |
Measures the insulation resistance of transformer windings.
| Specification | Value |
|---|---|
| Availability | option |
Assesses capacitance and power factor for transformers and bushings.
| Specification | Value |
|---|---|
| Availability | option |
Conducts high voltage withstand tests.
| Specification | Value |
|---|---|
| Availability | option |
Measures the dielectric strength of transformer oil.
| Specification | Value |
|---|---|
| Availability | option |
High voltage test leads for insulation assessment.
| Specification | Value |
|---|---|
| Length | 30 m |
Low voltage test leads for winding resistance and turns ratio.
| Specification | Value |
|---|---|
| Length | 30 m |

Provides additional safety for testing operations.

Monitors all safety-relevant parameters.
Safety equipment in accordance with BGI 891 and VDE 0104.

Supports various power supply configurations.
| Specification | Value |
|---|---|
| Voltage | 100-240 V |
| Frequency | 50-60 Hz |
Optional generator for independent power supply.
| Specification | Value |
|---|---|
| Power | 5 kVA and higher |
Conducts various insulation tests.
| Specification | Value |
|---|---|
| Test Voltage, DC | up to 5, 10 or 15 kV |
| Measurement Range | 100 kOhm…15 TOhm |
| Charging Current | 2 mA, 6 mA (short circuit) |
| Noise Immunity | 8 mA |
Measures capacitance and dissipation factor.
| Specification | Value |
|---|---|
| Test Voltage, AC | 0-12 kV |
| Test Current (at 12 kV) | 300 mA (4 minutes), 100 mA (continuous) |
| Test Frequency Range | 45-70 Hz (12 kV), 15-400 Hz (4 kV), 1-500 Hz (25 |
Tests winding resistance and OLTC.
| Specification | Value |
|---|---|
| Test Current | up to 10 A (optional up to 50 A) |
| Measurement Range | 1 μOhm – 2 kOhm |
| Accuracy | +/- 0.25% |
Measures turns ratio and phase deviation.
| Specification | Value |
|---|---|
| Excitation Voltage | up to 80 V |
| Ratio Measurement Range | 0.8 – 45000 |
| Phase Deviation | +/-90° |
| Accuracy | +/-0.1%... +/- 0.3% |
Tests voltage withstand capabilities.
| Specification | Value |
|---|---|
| AC Test Voltage | 0…100 kV |
| DC Test Voltage | 0…70 kV |
| Load Capacitance | 0.01-1.9 nF |
| Leakage Current Measurement | up to 100 mA |
| Max Power Consumption | 20 kVA |
Utilizes PowerDB for data management.

Runs on a basic operating system.
| Specification | Value |
|---|---|
| OS | WIN 7 |

Multiple interface options for connectivity.
| Specification | Value |
|---|---|
| — | RS 232, USB, Ethernet |
Provides backup power for the industrial PC.
| Specification | Value |
|---|---|
| Duration | 7 min |